Transformer Overload Capacity Explained: What IEEE C57.91 Actually Allows
Transformer overload capacity is a temperature question, not a percentage on a spec sheet. This guide breaks down how IEEE C57.91 calculates the winding hot spot during overload, what a 25% overload aOct 15, 2026 -

Transformer Protection Explained: Buchholz Relay, Sudden Pressure and Differe...
Buchholz relay, sudden pressure and differential protection catch the faults a transformer cannot show you. Failure data and specification traps.Oct 14, 2026 -

Compact Substation Selection Guide: What to Specify Before You Order a Prefab...
A compact substation puts MV switchgear, a distribution transformer and LV distribution into one type-tested enclosure - one foundation, one lift, one commissioning window.
This guide covers what IOct 13, 2026 -

Hydropower Transformer Selection for Pumped Storage Plants: A GSU Guide
Pumped storage duty breaks transformers that were specified for baseload. This guide covers generate versus pump mode, SFC harmonics, impedance and temperature-rise limits, cavern transport constraintOct 12, 2026 -

Microgrid Transformer Selection Guide: Sizing, Impedance and Grounding for Ca...
A microgrid transformer must survive two very different jobs: normal distribution duty, and carrying an entire facility with the utility breaker open. This guide covers island-mode sizing, load-blockOct 10, 2026 -

Pulp and Paper Mill Transformer Selection: Sizing for Refiner Starts, VFD Har...
Refiner starts, VFD harmonics and corrosive air decide pulp and paper mill transformer sizing.
A practical guide to refiner starting voltage dip, IEEE C57.110 harmonic derating, wet-end enclosure cOct 09, 2026 -

Transformer Loss Capitalization Explained: How No-Load and Load Loss Decide W...
Loss evaluation is not a new idea. IEEE C57.120-2017 sets out how to convert energy, power, financing and load pattern into dollars per kilowatt of loss. This guide runs the four-step calculation, shoOct 08, 2026 -

Transformer Certification for Middle East Projects: SASO SABER, G-Mark and IE...
In the Gulf a transformer needs three separate certificates before customs releases it, and a fourth approval before the project does. This guide covers G-Mark scope, the SABER product and shipment ceOct 08, 2026 -

Transformer Insulation Resistance Test and Polarization Index Explained: A Pr...
Commissioning a transformer is not a pass-or-fail stamp. This field guide explains what a transformer insulation resistance test really measures, how to read the polarization index and dielectric absoOct 07, 2026 -

Transformer Oil Moisture: Why the Same Unit Can Read 8 ppm and 22 ppm
Two oil samples from one transformer can read 8 ppm and 22 ppm a week apart and both be correct. Why transformer oil moisture moves with temperature, what IEEE C57.106 and IEC 60296 limits really coveOct 06, 2026 -

GIC and Power Transformers: How Geomagnetically Induced Currents Push Your Ho...
Geomagnetically induced currents (GIC) from solar storms push transformer winding hot spots past design limits. This guide explains how GMD events saturate the core, why the grid-level symptom is voltOct 05, 2026 -

Oil Immersed Transformers for Biomass and Waste-to-Energy Plants: Sizing Gene...
Biomass and waste-to-energy plants punish a transformer sized from a nameplate load list alone. This guide covers generator step-up duty for steam turbines, drive harmonics under IEEE 519, auxiliary tSep 30, 2026