Dry Type Transformer
Dry-type transformers are typically used in indoor applications where it is necessary to minimize the risk of fire or environmental contamination. They are commonly found in commercial buildings, hospitals, schools, and other locations where safety and environmental concerns are important.

The primary advantages of dry-type transformers
Safety
Since there is no liquid coolant involved, the risk of leaks, spills, and subsequent hazards is significantly reduced. This makes them more suitable for locations where fire safety is a concern.
Maintenance
Dry-type transformers require minimal maintenance compared to liquid-filled transformers. There is no need for periodic testing or replacement of liquid coolant, resulting in lower maintenance costs.
Environmental friendliness
Dry-type transformers do not contain any hazardous fluids, such as oil, which eliminates the risk of environmental contamination in case of leaks or spills. They are considered more environmentally friendly than liquid-filled transformers.
Overall,dry-type transformers offer a safer and more environmentally friendly alternative to liquid-filled transformers in certain applications. They are a popular choice where fire safety, maintenance convenience, and environmental concerns are paramount.
Differences between dry type and Liquid transformer
Cooling method
Dry-type transformers use natural convection or forced-air cooling to dissipate heat, while liquid-filled transformers utilize liquid coolant (typically oil) to absorb and dissipate heat.
Insulation material
Dry-type transformers employ solid insulation materials (such as epoxy resin) for insulation, whereas liquid-filled transformers rely on the liquid coolant for both cooling and insulation.
Safety
Due to the absence of liquid coolant, dry-type transformers are safer in terms of fire risk and environmental contamination. Liquid-filled transformers carry the risk of leaks, which can lead to fires or environmental pollution.
Maintenance requirements
Dry-type transformers generally require less maintenance compared to liquid-filled transformers. Liquid-filled transformers need regular inspections and maintenance of the liquid coolant's quality and performance.
Size and capacity
Liquid-filled transformers are typically used in higher power and capacity applications, while dry-type transformers are more suitable for lower power and capacity requirements.

RYAN Dry-type Transformer
Cast Resin Dry Type Transformer
Primary Voltage Ratings: 6-13.2/20-24/35-38.5 or others
Secondary Voltage Ratings: 0.2-0.6kv or orther
H.V. TAP RANGE: ±2×2.5%
CONNECTION TYPE: Dyn11 Yyn0
VPI Transformer
Rating :100 kVA to 20 MVA
Voltage Class:Up to 22 kV
Frequency :50/60 Hz
Cooling:AN/AF